#20421 new enhancement
Power preset additions for transfomer and power plant — at Version 9
Reported by: | Gazer75 | Owned by: | team |
---|---|---|---|
Priority: | normal | Milestone: | |
Component: | Internal preset | Version: | |
Keywords: | power transformer | Cc: | francois.lacombe |
Description (last modified by )
Original claim:
Could we get the the rating and windings added for primary, secondary and tertiary on transformers?
https://wiki.openstreetmap.org/wiki/Tag:power%3Dtransformer#Tagging
I'd also like to see a box for owner on power plant menu. The owner and operator of such facilities are often not the same.
Following the approval of https://wiki.openstreetmap.org/wiki/Proposed_features/Transformers_classification_refinement, it would be great to add the following changes as well please:
- Discourage transformer=traction, transformer=auto, transformer=minor_distribution
- Carefully replace transformer=distribution when installed in an actual substation (an area with power=substation on it)
- Update pole with transformer preset with transformer=distribution or transformer=main (currently only with transformer=distribution). Transformer=auxiliary isn't covered as it comes with other significant equipment (switches mostly).
- transformer=auxiliary is no more restricted to power=substation perimeters and can be used standalone as well (probably no change in JOSM validation).
- Create transformer=main https://wiki.openstreetmap.org/wiki/Tag%3Atransformer%3Dmain
- Create windings:auto=yes https://wiki.openstreetmap.org/wiki/Key:windings:auto
Change History (9)
comment:1 by , 5 years ago
Component: | Core → Internal preset |
---|---|
Keywords: | power transformer added |
comment:2 by , 4 years ago
comment:3 by , 4 years ago
Cc: | added |
---|
Still only low numbers.
owner=*
is ignored, so far, and is worth an own ticket as it is not tied to power tagging.
comment:4 by , 4 years ago
Dear all
It's true power transformers tagging is expert stuff and could confuse most of osm mappers.
We could at least improve the power=transformer preset with windings:primary and windings:secondary beside windings=* that must remain in the preset.
However, this ticket should be paused until this proposal has been voted. A few details remain to be fixed but it is almost done.
https://wiki.openstreetmap.org/wiki/Proposed_features/Transformers_classification_refinement
+1 for owner=* on different ticket (and valuable for any power=* asset, not just power plants).
Best regards
comment:6 by , 4 years ago
Yes, the current proposal was accepted :)
Thank you Skyper for your support
I can update this ticket (once documentation completed), or create a separate one if you mind.
Final changelist is:
- Discourage transformer=traction, transformer=auto, transformer=minor_distribution
- Carefully replace transformer=distribution when installed in an actual substation
- Create transformer=main
- Create windings:auto=yes
We'll be able to add transformer=compensator as proposed by Gazer75 once documented too.
See #21836 as well for additional deprecation.
All the best
comment:8 by , 3 years ago
Description: | modified (diff) |
---|
Good Skyper, ticket was updated and wiki is up to date :)
comment:9 by , 3 years ago
Description: | modified (diff) |
---|
I've updated the description : I forgot to mention the pole with transformer preset.
Best regards
I am not sure if all these subtags are suitable for defaultpresets, for now, especially the ones with low numbers in use.
Maybe, an external preset hosted on this wiki is a better solution for these special tags with low numbers or if only "in use" or "proposed" but not "approved".