Ignore:
Timestamp:
2026-07-23T17:52:56+02:00 (2 days ago)
Author:
stoecker
Message:

fix #20421 - patch by francois.lacombe - Power preset additions for transfomer and power plant

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/resources/data/defaultpresets.xml

    r19563 r19590  
    66206620            <key key="pipeline" value="substation" />
    66216621            <text key="name" text="Name" />
    6622             <combo key="substation" text="Type" values="compression,distribution,field_gathering,inspection_gauge,measurement,valve,valve_group" values_context="pipeline" values_searchable="true" />
     6622            <combo key="substation" text="Role of substation" values="compression,distribution,field_gathering,inspection_gauge,measurement,valve,valve_group" values_context="pipeline" values_searchable="true" />
    66236623            <reference ref="ref_operator" />
    66246624            <reference ref="substance" />
     
    71287128            <key key="power" value="substation" />
    71297129            <text key="name" text="Name" />
    7130             <combo key="substation" text="Type of substation" values="compensation,converter,distribution,industrial,minor_distribution,traction,transition,transmission" values_context="power" />
     7130            <combo key="substation" text="Role of substation" values="compensation,converter,distribution,industrial,minor_distribution,traction,transition,transmission" values_context="power" />
    71317131            <reference ref="power_loc" />
    71327132            <reference ref="voltage_frequency" />
     
    71427142            <space />
    71437143            <key key="power" value="transformer" />
    7144             <combo key="transformer" text="Type of transformer" values="auxiliary,converter,distribution,generator,main,phase_angle_regulator,yes" match="key" values_context="power" />
     7144            <combo key="transformer" text="Nature of transformer" values="auxiliary,converter,distribution,generator,main,phase_angle_regulator,yes" match="key" values_context="power" />
    71457145            <reference ref="power_loc" />
    71467146            <reference ref="transformer_voltage_frequency" />
     
    72997299            <space />
    73007300            <label text="Transformer Attributes:" />
    7301             <key key="transformer" value="distribution" match="key!" />
     7301            <key key="transformer" value="distribution" match="keyvalue!" />
    73027302            <reference ref="transformer_voltage_frequency" />
    73037303            <reference ref="optional_transformer_rating_phases_devices_windings" />
    73047304        </item> <!-- Pole with Transformer -->
     7305        <item name="Pole with Substation" icon="presets/power/pole_transformer.svg" type="node" preset_name_label="true">
     7306            <link wiki="Tag:power=pole" />
     7307            <space />
     7308            <key key="power" value="pole" />
     7309            <label text="Pole Attributes:" />
     7310            <reference ref="power_pole" />
     7311            <space />
     7312            <label text="Substation Attributes:" />
     7313            <combo key="substation" text="Role of substation" values="industrial,minor_distribution" match="key!" />
     7314            <space />
     7315            <label text="Transformer Attributes:" />
     7316            <combo key="transformer" text="Nature of transformer" values="main" match="none" />
     7317            <reference ref="transformer_voltage_frequency" />
     7318            <reference ref="optional_transformer_rating_phases_devices_windings" />
     7319        </item> <!-- Pole with Substation -->
    73057320        <item name="Catenary mast" icon="presets/power/catenary_mast.svg" type="node" preset_name_label="true">
    73067321            <link wiki="Tag:power=catenary_mast" />
Note: See TracChangeset for help on using the changeset viewer.