Changes between Version 54 and Version 55 of Presets/Power_Mapping_Utility_Simple
- Timestamp:
- 2022-02-07T21:47:11+01:00 (14 months ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
Presets/Power_Mapping_Utility_Simple
v54 v55 16 16 <combo key="rating" values="1600,1500,1000,500,400,300,315,250,200,150,100,50" display_values="1600,1500,1000,500,400,300,315,250,200,150,100,50" text="Power Rating/Capacity(kVA)" /> 17 17 <space /> 18 <text key="voltage -high" text="Primary/Input Voltage" />18 <text key="voltage:primary" text="Primary/Input Voltage" /> 19 19 <space /> 20 <text key="voltage -low" text="Secondary/Output Voltage" />20 <text key="voltage:secondary" text="Secondary/Output Voltage" /> 21 21 <space /> 22 22 <combo key="operator" text="Feeder Name" values="BAMBI, COTEX, DOLE, FUMBA, JANGOMBE, KILIMAHEWA, MPENDAE, MARUHUBI,MAZIZINI,NEW FUMBA,NEW NORTH,NEW SOUTH,OLD NORTH,OLD SOUTH,SAATENI 5,SAATENI 6"/> … … 34 34 <combo key="operator" text="Feeder Name" values="BAMBI, COTEX, DOLE, FUMBA, JANGOMBE, KILIMAHEWA, MPENDAE, MARUHUBI,MAZIZINI,NEW FUMBA,NEW NORTH,NEW SOUTH,OLD NORTH,OLD SOUTH,SAATENI 5,SAATENI 6"/> 35 35 <space/> 36 <combo key="cables" text="Amount of Cables" values="single,double,triple,quad,fivefold,eightfold" /> 36 <text key="cables" text="Amount of conductors" /> 37 <combo key="wires" text="Amount of wires per conductor" values="single,double,triple,quad,fivefold,eightfold" /> 37 38 <combo key="power:gauge" text="Conductor Size specified in mm" values="100,150" /> 38 39 … … 43 44 44 45 <key key="power" value="minor_line" /> 45 <text key="name" text=" TransformerName" />46 <text key="name" text="Line Name" /> 46 47 <space/> 47 48 <text key="voltage" value="415" text="Voltage" /> … … 52 53 <text key="ref" text="Equipment ID" /> 53 54 <text key="ref:upriser" text="LV Unit or Upriser" values="1,2,3,4" /> 54 <combo key="cables" text="Amount of Cables" values="single,double,triple,quad,fivefold,eightfold" /> 55 <text key="cables" text="Amount of conductors" /> 56 <combo key="wires" text="Amount of wires per conductor" values="single,double,triple,quad,fivefold,eightfold" /> 55 57 <combo key="power:gauge" text="Conductor Size specified in mm" values="100,150" /> 56 58 </item> … … 84 86 <text key="generator:source" text="Source Type " /> 85 87 <space /> 86 <text key="generator: capacity" text="Capacity (MW) " />88 <text key="generator:output:electricity" text="Electric capacity (MW) " /> 87 89 <space /> 88 90 <text key="ref" text="Equipment ID" />