Description (last modified by francois.lacombe)

Hi,

An extension proposal had been accepted regarding power transformer mapping. Both power transformer and power pole with transformer presets should be updated.
https://wiki.openstreetmap.org/wiki/Proposed_features/Transformer_extension_proposal

Tagging of power=transformer has been updated accordingly
https://wiki.openstreetmap.org/wiki/Tag:power%3Dtransformer#Tagging

User should be prompted for the following tags (with according label), out of casual ones :

  • transformer= {distribution, generator, converter, traction, auto, phase_angle_regulator, auxiliary, yes} (Function of transformer)
  • location=* (Transformer location)
  • phases=* (Number of phases)
  • frequency=* (Operating frequency)
  • voltage:primary=* (Primary "power plant side" voltage)
  • voltage:secondary=* (Secondary "consumer side" voltage)
  • voltage:tertiary=* (Tertiary "auxiliary side" voltage)
  • windings=* (Number of windings)
  • windings:configuration = {star, delta, open-delta, zigzag, open, scott, leblanc} (Windings configuration)
  • rating=* (Rating in VA)
  • devices=* (Number of different transformer devices)

voltage=* key shouldn't be used any more on power transformers.

Additionally, some validation rules should be created as follow and warn users :

  • Check rating=* is given in VA and without any unit in the value (like multiples kVA, MVA,...)
  • Check voltage=* isn't associated with power=transformer or transformer keys

Thank you in advance to take care of this, all the best.

Attachments (0)

Change History (5)

comment:1 Changed 3 months ago by francois.lacombe

Description: modified (diff)

comment:2 Changed 3 months ago by francois.lacombe

Component: External presetInternal preset

comment:3 Changed 6 weeks ago by Penegal

I agree with that request, especially the new voltage:* tagging, which significantly improves power tagging.

@francois.lacombe: I think the only check to do about rating is that it must be a number, as JOSM won't be able to check by itself if it's in VA.

comment:4 Changed 6 weeks ago by Penegal

I might add that, for poles with transformer, a switch=* preset could be very useful, as these poles often have switches to cut the line departing from the transformer.

comment:5 Changed 6 weeks ago by francois.lacombe

Hi Penegal,

Please read this about the power preset on iD where I try to convince them about rating without unit tagging.
https://github.com/openstreetmap/iD/issues/4442
I definitely believe it's great, but that's not everyone opinion.

I write you a more detailed mail about low volvate circuit breakers beside transformers.

Francois

Modify Ticket

Change Properties
Set your email in Preferences
Action
as new The owner will remain team.
as The resolution will be set.
to The owner will be changed from team to the specified user.
The owner will change to francois.lacombe
as duplicate The resolution will be set to duplicate.The specified ticket will be cross-referenced with this ticket
The owner will be changed from team to anonymous.

Add Comment


E-mail address and name can be saved in the Preferences.

 